Abstract

The performance of an apodized gas sensor is demonstrated through simultaneous detection of CO and CO2 absorption lines around 1.57 µm in the recuperator channel of a gas-fired industrial furnace at Shahid Montazeri power plant (SMPP) industry. This led to the concentration measurement of targeted molecules as less than ~ 1% and 9.5%, respectively, at atmospheric pressure and 350 °C, indicating close consistency with the reference data reported by SMPP. A minimum detectable absorption of ~ 0.4 × 10−3, corresponding to a detection sensitivity of ~ 4.8 × 10−9 cm−1 Hz−1/2 is measured in this application.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.