Abstract

The steps in t he applied voltages of a three-phase, inverter-induction motor drive system cause undesirable pulsations in motortor By using multiple inverters connected to a multiphase machine with appropriate winding displacements, significant improvement in system performance is possible. The winding displacements required, however, are not necessarily the symmetrical displacements used in standard multiphase machines. This paper sets forth an improved method for analyzing many types of unsymmetrical, as well as symmetrical, multiphase induction machines. The simulation of a 7.5-hp induction machine with two three-phase sets of stator windings fed from two six-step inverters illustrates the application of the method of analysis and shows how the machine torque characteristic may be improved by proper spacing of the winding sets.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.