Abstract
Indoor radon surveying and remediation were implemented in a single-family home affected by high levels of indoor radon in the Celleno municipality (central Italy) with the aim of identifying the contribution of radon sources, evaluating the factors affecting radon entry into the building, and reducing radon risk. Average radon levels were relatively low at the ground floor (286 ± 202 Bq m−3) and first floor (167 ± 84 Bq m−3) in autumn when the temperature was still warm and the windows were open, but increased up to 2776 ± 1768 Bq m−3 and 970 ± 202 Bq m−3 in the first half of December, when the heating system was on and the windows were closed. The inner walls of the pilot room at the ground floor, semi buried on one side, were then treated with a waterproof product (a silane terminated polymer) and the average radon was halved (1475 ± 1092 Bq m−3) in the following month, which was still characterised by winter conditions. Radon entry in the room was identified and sealed with the same product, and a radon accumulation space behind a NE-SW oriented wall was naturally ventilated, reducing radon below the reference level in April with northerly winds conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.