Abstract

To test the relation of indoor radon concentration to fault zone, a survey was conducted in selected buildings in Vydrník, situated close to the neotectonically active Vikartovce fault trace. Monitoring was performed using RamaRn track detectors during a period of 1 year. Annual average of indoor radon ranged from 60 to 940Bq/m3, with an average of 160Bq/m3. Seasonal variation of indoor radon concentration was confirmed, with minimum in summer (June-August). The results confirmed that radon concentration in rooms above the cellar was lower than in rooms with the direct contact with subsoil. High indoor radon up to 940Bq/m3 was detected only in one of monitored houses situated close to the generally E-W trending Vikartovce fault and can be attributed to this fault zone used as pathway for radon migration. Influence of nearby situated NW-SE trending crosscutting fault on radon concentration is probable too.