Abstract
The indoor radon concentrations in Kirklareli, Turkey were measured in living rooms of 19 houses during winter in 2019 using Airthings 222 Corentium Home Radon Gas Detector. The short-term and long-term measurements were performed in 1 and 7 days for each house to investigate radioactive radon gas exposure in Kirklareli buildings. The indoor radon concentrations were varied from 23 to 156 Bq m-3 for 1 day period and were varied from 16 to 77 Bq m-3 for 7 days period. The average radon gas concentration was found as 43.5 Bq m-3 and this result is higher than the average of Turkey and the world average. The annual effective doses due to radon gas exposure were also estimated. The annual effective dose rate ranged from 0.61 to 2.94 mSv y-1 with a mean value of 1.09 mSv y-1.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.