Abstract

An index to evaluate indoor noise level reduction with an open window Noise Reduction Index (NRI) was proposed [Buratti C. Indoor Noise Reduction Index with open window. Appl Acoust 2002;63(4):431–51]. The reduction was due to the installation of a false ceiling in the room, thus reducing the contribution of the reverberant field. Experimental data related to two different kinds of false ceiling were compared to the results obtained by an original calculation model. Good agreement was found between experiments with two different materials and predictions. The present paper examines six different kinds of false ceiling and arrives at a new validation of the model. Calculations of NRI show good agreement with experimental data: a maximum difference of −1.2 dB(A) was found with a mean difference of 0.5 dB(A) for a wide range of absorption coefficient values. Hence the model represents a reliable instrument for indoor NRI prediction, if the acoustic absorption characteristics of materials are known.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.