Abstract

Volatile organic compounds (VOCs) have been measured in a freshly carpeted 20-m[sup 3] stainless-steel room in both the absence and presence of ozone (ozone concentrations ranging from 30 to 50 ppb, with one experiment conducted at 400 ppb). Four different types of carpeting were exposed, and in each set of experiments, the room was ventilated at 1 air exchange/h. The gas-phase concentrations of selected carpet emissions (e.g., 4-phenylcyclohexene, 4-vinylcyclohexene, and styrene) significantly decreased in the presence of ozone. Conversely, the concentrations of other compounds (e.g., formaldehyde, acetaldehyde, and aldehydes with between 5 and 10 carbons) significantly increased. Furthermore, the total concentration of VOCs increased markedly in the presence of ozone. The additional VOCs appear to have been generated by reactions between ozone and relatively nonvolatile compounds associated with the carpets. These studies suggest that VOCs measured within a building at elevated ozone levels (>30 ppb) may differ from those measured at lower ozone levels (<10 ppb). 12 refs., 2 figs., 6 tabs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.