Abstract

Annular denuder-filter pack sampling systems were used to make indoor and outdoor measurements of aerosol strong H+, SO4(2-), NH4+, NO3- and NO2-, and the gaseous pollutants SO2, HNO3, HONO and NH3 during summer and winter periods in Boston, Massachusetts. Outdoor levels of SO2, HNO3, H+ and SO4(2-) exceeded their indoor concentrations during both seasons. Winter indoor/outdoor ratios were lower than during the summer, probably due to lower air exchange rates during the winter period. During both monitoring periods, indoor/outdoor ratios of aerosol strong H+ were 40-50 percent of the indoor/outdoor SO4(2-) ratio. Since aerosol strong acidity is typically associated with SO4(2-), this finding is indicative of neutralization of the acidic aerosol by the higher indoor NH3 levels. Geometric mean indoor/outdoor NH3 ratios of 3.5 and 23 respectively were measured for the summer and winter sampling periods. For HONO, NH3, NH4+ and NO2-, indoor concentrations were significantly higher than ambient levels. Indoor levels of NO3- were slightly less than outdoor concentrations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call