Abstract

The purpose of this work is to assess, both experimentally and theoretically the status of air quality in a dentistry clinic of the Athens University Dentistry Faculty with respect to chemical pollutants and identify the indoor sources associated with dental activities. Total VOCs, CO(2), PM(10), PM(2.5), NO(x) and SO(2) were measured over a period of approximately three months in a selected dentistry clinic. High pollution levels during the operation hours regarding CO(2), total VOCs and Particulate Matter were found, while in the non-working periods lower levels were recorded. On the contrary, NO(x) and SO(2) remained at low levels for the whole experimental period. These conditions were associated with the number of occupants, the nature of the dental clinical procedures, the materials used and the ventilation schemes, which lead to high concentrations, far above the limits that are set by international organizations and concern human exposure. The indoor environmental conditions were investigated using the Computational Fluid Dynamics (CFD) model PHOENICS for inert gases simulation. The results revealed diagonal temperature stratification and low air velocities leading to pollution stratification, accompanied by accumulation of inert gaseous species in certain areas of the room. Different schemes of natural ventilation were also applied in order to examine their effect on the indoor comfort conditions for the occupants, in terms of air renewal and double cross ventilation was found to be most effective. The relative contribution of the indoor sources, which are mainly associated with indoor activities, was assessed by application of the Multi Chamber Indoor Air Quality Model (MIAQ) to the experimental data. It was found that deposition onto indoor surfaces is an important removal mechanism while a great amount of particulate matter emitted in the Clinic burdened severely the indoor air quality. The natural ventilation of the room seemed to reduce the levels of the fine particles. The emission rates for the fine and coarse particulates were found to be almost equal, while the coarse particles were found susceptible to deposition onto indoor surfaces.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.