Abstract
BackgroundAim of this study was to evaluate feasibility and effects of individualised flow-controlled ventilation (FCV), based on compliance guided pressure settings, compared to standard of pressure-controlled ventilation (PCV) in a porcine intra-abdominal hypertension (IAH) model. The primary aim of this study was to investigate oxygenation. Secondary aims were to assess respiratory and metabolic variables and lung tissue aeration.MethodsPigs were randomly assigned to FCV (n = 9) and PCV (n = 9). IAH was induced by insufflation of air into the abdomen to induce IAH grades ranging from 0 to 3. At each IAH grade FCV was undertaken using compliance guided pressure settings, or PCV (n = 9) was undertaken with the positive end-expiratory pressure titrated for maximum compliance and the peak pressure set to achieve a tidal volume of 7 ml/kg. Gas exchange, ventilator settings and derived formulas were recorded at two timepoints for each grade of IAH. Lung aeration was assessed by a computed tomography scan at IAH grade 3.ResultsAll 18 pigs (median weight 54 kg [IQR 51–67]) completed the observation period of 4 h. Oxygenation was comparable at each IAH grade, but a significantly lower minute volume was required to secure normocapnia in FCV at all IAH grades (7.6 vs. 14.4, MD − 6.8 (95% CI − 8.5 to − 5.2) l/min; p < 0.001). There was also a significant reduction of applied mechanical power being most evident at IAH grade 3 (25.9 vs. 57.6, MD − 31.7 (95% CI − 39.7 to − 23.7) J/min; p < 0.001). Analysis of Hounsfield unit distribution of the computed tomography scans revealed a significant reduction in non- (5 vs. 8, MD − 3 (95% CI − 6 to 0) %; p = 0.032) and poorly-aerated lung tissue (7 vs. 15, MD − 6 (95% CI − 13 to − 3) %, p = 0.002) for FCV. Concomitantly, normally-aerated lung tissue was significantly increased (84 vs. 76, MD 8 (95% CI 2 to 15) %; p = 0.011).ConclusionsIndividualised FCV showed similar oxygenation but required a significantly lower minute volume for CO2-removal, which led to a remarkable reduction of applied mechanical power. Additionally, there was a shift from non- and poorly-aerated lung tissue to normally-aerated lung tissue in FCV compared to PCV.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.