Abstract
A newly developed apparatus permits the differentiated transparency measurement of stripped horny layer material. An adhesive tape strip, covered with a stripped horny layer mass, is fixed on a glass plate and led past a homogenous light source and a photo cell at a constant speed, whereby each respective light-current deviation is collected as a parameter for each respective strip model. It is then synchronously registered via a continuous-line-recorder. The systematic evaluation of original curves results in a reproducible individual horny layer model obtained by a methodically stripped adhesive tape series, successively taken under constant conditions from the same skin area. Three characteristic types of curves were observed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.