Abstract
In multiple operation stamping processes, a press tonnage signal measured by press tonnage sensors installed on press linkages/uprights, is the summation of die forces at all stations. Different from the current practice of using a whole cycle of press tonnage signals to monitor the compound condition of all stations, this paper proposes a new method to use the partitioned monitoring segments of press tonnage signals to monitor individual station conditions. For this purpose, a generic signal segmentation principle is proposed, and the Hotelling T2 control charts are developed with consideration of the interactions among stations. A real case study of a doorknob stamping process is provided to demonstrate analysis procedures and effectiveness of the developed methodology.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.