Abstract
Simultaneous, on-frequency masking is commonly assumed to be linear with increasing noise intensity. However, some evidence suggests that, expressed in terms of signal-to-noise ratio changes with background level changes, masking slopes can vary from 0 dB/dB. These results and evidence from a large sample of subjects with normal and impaired hearing demonstrate level-dependent changes in masking, large individual differences in masking among subjects with similar thresholds in quiet, and significant correlations of masking slope with other estimates of auditory function measured in the same backgrounds.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.