Abstract
In this work, a method was developed for indirectly estimating contact angles of sessile liquid drops on convex and concave surfaces. Assuming that drops were sufficiently small that no gravitational distortion occurred, equations were derived to compute intrinsic contact angles from the radius of curvature of the solid surface, the volume of the liquid drop, and its contact diameter. These expressions were tested against experimental data for various liquids on polytetrafluoroethylene (PTFE) and polycarbonate (PC) in the form of flat surfaces, spheres, and concave cavities. Intrinsic contact angles estimated indirectly using dimensions and volumes generally agreed with the values measured directly from flat surfaces using the traditional tangent method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.