Abstract

The indirect current control scheme has evolved from the success of the hysteresis current controlled voltage regulated rectifier, which has been shown to be capable of: unity and even leading power factor operation; near sinusoidal current waveforms; and bilateral power transfer without the need of bi-directional solid state power switches. The advance consists of replacing the inner hysteresis current feedback loop by the standard sinusoidal PWM control and in the process saving the cost of the current measuring transducers. The scheme is evaluated through tests on 1 KW size laboratory models and through digital simulations. A theory of the system dynamics is developed and stability boundaries are presented. >

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call