Abstract

In this paper, an indirect control strategy for multilevel cascaded H-bridge rectifiers is introduced. The indirect control does not need any current sensors, hence the system reliability increases. Using this method, controllable power factor with nearly sinusoidal ac current could be achieved. All dc link voltages are regulated to a constant reference voltage, even if they consume various amounts of power. In the proposed strategy, the multicarrier phase-shifted sinusoidal pulsewidth modulation (MPS-SPWM) technique is used in order to eliminate low order harmonics, while the maximum switching frequency is limited to 500Hz. Additionally, no extra ac filters are needed at the ac side since the total harmonic distortion is below 5%. To verify the validity and effectiveness of the proposed control strategy, several simulations are carried out on a 7-level cascaded H-bridge rectifier in PSCAD/EMTDC environment.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.