Abstract

An indirect complexo-titrimetric method is described for the determination of palladium in the presence of other metal ions, L-histidine being used as the masking agent. Palladium(II) and other metal ions are initially complexed with an excess of EDTA and the surplus EDTA titrated with standard zinc sulfate solution at pH 4.5–5.5 using xylenol orange as indicator. An excess of 1 % L-histidine solution is then added, and the released EDTA is titrated with standard zinc sulfate solution. Accurate and reproducible results were obtained for 2–15 mg of Pd with relative errors ⩽0.4% and standard deviations < 0.02mg. Sn(IV) and Au(III) interfere, but can be easily masked. The method is successfully applied for the determination of palladium(II) in alloy compositions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.