Abstract

The results of a bilateral comparison of 10 V Josephson array voltage standards of the Ulusal Metroloji Enstitüsü (TÜBTAK-UME, Turkey) and the Bureau National de Métrologie-Laboratoire Central des Industries Électriques (BNM-LCIE, France), in the framework of EUROMET Project No. 469, are reported. A set of four Zener-diode-based voltage reference standards (Fluke 732B), delivered by the UME, was used as a transfer standard between the two laboratories. The results show an agreement within 97 nV with an overall uncertainty (1 σ) of 98 nV.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.