Abstract

Accuracy in the liquid hydrocarbons custody transfer is mandatory because it has a great economic impact. By far the most accurate meter is the positive displacement (PD) meter. Increasing such an accuracy may adversely affect the cost of the custody transfer, unless simple models are developed in order to lower the cost, which is the purpose of this work. PD meter consists of a fixed volume rotating chamber. For each turn a pulse is counted, hence, the measured volume is the number of pulses times the volume of the chamber. It does not coincide with the real volume, so corrections have to be made. All the corrections are grouped by a meter factor. Among corrections highlights the slippage flow. By solving the Navier-Stokes equations one can find an analytical expression for this flow. It is neither easy nor cheap to apply straightforward the slippage correction; therefore we have made a simple model where slippage is regarded as a single parameter with dimension of time. The model has been tested for several PD meters. In our careful experiments, the meter factor grows with temperature at a constant pace of 8×10−5 °C−1. Be warned because the equipment manuals cite half of the pace.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.