Abstract
Emergency escape roof hatches are used to evacuate school buses in rolled-over orientations. In the United States, the minimum opening size of a roof hatch is defined by Federal Motor Vehicle Safety Standard (FMVSS) no. 217. With the prevalence of rising obesity rates among children, the minimum roof hatch opening size may not be large enough to accommodate larger passengers. Post-accident conditions such as injuries, disorientation, and exit obstructions may also prevent unobstructed passage for egress within acceptable time limits. The purpose of this study was to redesign and fabricate a roof hatch with a larger opening and evaluate its egress characteristics for a range of typical school bus passengers. The larger roof hatch opening allows greater evacuation flow rates, and is almost functionally equivalent to the evacuation flow rate of the front door on an upright school bus.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.