Abstract

To improve the bondability and ball-shear force of gold balls that are thermosonically bonded to copper electrodes over flex substrates, a nickel layer was deposited on the surface of the copper electrodes to increase their rigidity. A silver layer was then deposited on the nickel layer to prevent oxidation of the copper electrodes during the thermosonic bonding process. This nickel layer was expected to enhance the rigidity of copper electrodes over the flex substrates, increasing the thermosonic bonding efficiency of gold balls to copper electrodes over the flex substrates. Deposition the nickel layer on the copper electrodes improved the elastic modulus of the flex substrates, indicating that the nickel layer is effective in enhancing the rigidity of copper electrodes over the flex substrates. The bondability and ball-shear force of gold balls that are thermosonically bonded to copper electrodes increases with the thickness of the nickel layer given fixed bonding parameters. One hundred percent bondability and high ball-shear force can be achieved when gold balls are thermosonically bonded to copper electrodes with the deposition of a 0.5 μm-thick nickel layer. Herein, the ball-shear force was higher than that specified in JEDEC standards. Furthermore, gold balls that were thermosonically bonded to copper electrodes with a nickel layer had a large bonded area with an extensive scrape, while gold balls that were thermosonically bonded to copper electrodes without a nickel layer had a blank surface morphology. This experimental result was similar to that of tests of the elastic modulus of flex substrates, similarity can be used to explain that the effectiveness of the nickel layer in increasing the rigidity of copper electrodes, increasing the bonding efficiency at the bonding interface between gold balls and copper electrodes during thermosonic bonding process. After ball-shear test, a layer that was stuck on the ball bond was observed at the location of fracture of the ball bonds for gold balls they were thermosonically boned on copper electrodes with 0.5 μm-thick nickel layer. This observation implies that the ball-shear force of the gold balls that were bonded on the copper electrodes exceeded even the adhesive force of the layers that were deposited on the copper electrodes. The deposition of a 0.5 μm-thick nickel layer on copper electrodes over flex substrates improved the rigidity of the copper electrodes; the ultrasonic power could be propagated to the bonding interface between the gold balls and the copper electrodes, increasing the bondability and ball-shear force.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.