Abstract

The technology of selective plasma etching was applied to increase the surface roughness of graphite/polymer composite. Etching was performed with a low pressure weakly ionised oxygen plasma created with a RF generator of the output power of 200 W and frequency of 27.12 MHz. The density of charged particles, density of neutral oxygen atoms and the electron temperature was about 1×10 16 m −3, 4×10 21 m −3, and 5 eV, respectively. The effects of plasma treatment were observed by scanning electron microscope (SEM), electron microprobe (EMPA) and Talysurf. It was found that the surface roughness was increased by approximately 15 times, from a virgin sample at the roughness of R a =0.27 μm to a very rough surface with R a =4 μm. The roughness increased with increasing plasma exposure time. The EMPA results showed that the amount of sulphur in the surface layer decreased with increasing etching time indicating that PPS polymer was the material etched preferentially.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.