Abstract

Crystalline hydroxyapatite thin coatings have been prepared using a novel opposing RF magnetron sputtering approach at room temperature. X-ray diffraction (XRD) analysis shows that all the principal peaks are attributable to HA, and the as-deposited HA coatings are made up of crystallites in the size range of 50-100nm. Fourier transform infrared spectroscopy (FTIR) studies reveal the existence of phosphate, carbonate and hydroxyl groups, suggesting that HA coatings are highly crystalline. To study the biocompatibility of these coatings, murine osteoblast cells were seeded onto various substrates. Cell density counts using fluorescence microscopy show that the best osteoblast proliferation is achieved on an HA RAMS-coated titanium substrate. These experiments demonstrate that RAMS is a promising coating technique for biomedical applications.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.