Abstract

It was the aim of this study to evaluate the effect of different devices on the metal concentration in exhaled breath condensate (EBC) and to prove whether working conditions in different welding companies result in diverse composition of metallic elements. The influence of two collection devices (ECoScreen, ECoScreen2) on detection of metallic elements in EBC was evaluated in 24 control subjects. Properties of ECoScreen and a frequent use can alter EBC metal content due to contamination from metallic components. ECoScreen2 turned out to be favourable for metal assessment. Concentrations of iron, nickel and chromium in EBC sampled with ECoScreen2 were compared between non-exposed controls and industrial welders. Metal concentrations in EBC were higher in 36 welders recruited from three companies. Exposure to welding fumes could be demonstrated predominantly for increased iron concentrations. Concentrations of iron and nickel differed by working conditions, but chromium could not be detected in EBC.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.