An increased illuminance at the workplace is often said to be linked to an increase in productivity. We investigated this relationship in 23 workers on a production line in a car factory. Measurements of visual performance (visual acuity, colour vision and contrast sensitivity), a physiological assessment of alertness and subjective assessments of four parameters of well-being were made during the daytime shift under three illuminances (500 lux, 1500 lux and 2500 lux). The physiological alertness results and all but one of the subjective parameters showed no significant differences between the three illuminance conditions. Subjective alertness was the only parameter that was rated to be significantly greater at 2500 lux than at 500 lux. The utilisation of higher illuminances in the workplace should be carefully considered before being implemented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.