Abstract

Health care workers wear protective clothing when caring for patients with infectious diseases. However, during the action of patient care, the generated contact pressure may damage the surface of the protective clothing. Fabrics of protective clothing were damaged by a machine using a force similar to the contact pressure that occurs during nursing care. A total of 50 μL of blood containing methicillin-resistant Staphylococcus aureus (MRSA) (5 × 106 colony-forming units/mL) was dropped onto the pressed or rubbed fabrics. After removing the blood, the residual bacterial count on the surface of the clothing was measured. In the undamaged fabrics, the number of adherent MRSA was significantly higher on class 6 protective clothing than on the other tested clothing. The number of adherent MRSA significantly increased on the rubbed surgical gown and rubbed class 3 protective clothing than on the undamaged clothing. Because the damaged fabrics of protective clothing may cause bacterial carryover, health care workers should pay attention to preventing self-contamination when doffing the protective clothing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.