Abstract

In an advanced acoustics laboratory course at Brigham Young University, students are introduced to ANSI measurement standards in the context of sound power. They are introduced to the anatomy of a typical acoustics standard and then plan and carry out sound power measurements of an electric leaf blower using both reverberation chamber and sound intensity methods. The students are required to write a technical memorandum describing a) the blower’s radiated sound power levels over an appropriate frequency range, as obtained with the two methods; b) setup documentation and deviations from the standards’ recommended practices; and c) how any deviations might have contributed to discrepancies between the sound power levels obtained with the two methods. In this paper, a description of the experience is given, along with overall impressions and plans for future improvements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.