Abstract

Atypical femoral fractures (AFFs) are associated with prolonged bisphosphonate therapy. A feature of incomplete AFF is a localized periosteal reaction. It has been suggested that extending the length of the femur image at the time of dual-energy X-ray absorptiometry (DXA) may diagnose an incomplete AFF. In patients older than 50 yr on bisphosphonate therapy for more than 5 yr, we extended femur length at the time of routine DXA. Abnormal DXA images were suggested in 19 of 257 patients (7.4%). On X-ray, 7 patients (2.7%) showed no abnormality, 7 patients (2.7%) showed evidence of AFF, and 5 patients (2.0%) showed an unrelated radiographic abnormality. Of the 7 cases with X-ray evidence of AFF, 5 had a periosteal flare and 2 had a visible fracture line, both of whom needed insertion of an intramedullary nail. We demonstrated that it is feasible to detect incomplete AFF early using extended femur length imaging with a prevalence in our sample of 2.7% (95% confidence interval: 1.7%–3.7%).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.