The interaction of building components is difficult to predict. In the fast‐paced industries of design and build, the time is not often allotted to research the performance of individual building components, much less the interaction of components. To exacerbate the situation, specified materials are often improperly substituted with inferior or inappropriate products. Furthermore, the quality of the delivered materials is often not checked. The use of incompatible, improper, or inferior materials typically results in performance failures, which are often never realized by the designer, contractor, and owner. This paper presents a case study of the corrosion failure of galvanized roof components in a ballasted single‐ply roof system. The case study illustrates what can go wrong in the construction of a typical facility, and what steps were taken to identify positively the cause of a particular problem prior to the consideration of a permanent repair.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.