Abstract

Hydrogen concentrations of 0 up to 350mg∕kg in a titanium alloy have been determined at National Institute of Standards and Technology (NIST) with neutron incoherent scattering (NIS) and with cold neutron prompt gamma activation analysis. The latter is a well-established technique, while the former was demonstrated earlier at NIST by counting the neutrons scattered under 45° or 60° and establishing a linear relationship between hydrogen concentration and count rate. In this paper, it is shown that the NIS response is complicated by the dependence of the apparent hydrogen scattering cross section on the sample temperature and the hydrogen chemical binding. It is demonstrated that detection of scattered neutrons at two different angles as well as a more complex theoretical approach (i.e., including Monte Carlo modeling with the free-gas model) are required to correctly interpret NIS measurements. As a result, the process of matching standards and samples becomes less critical.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.