Abstract
Small‐scale physical models are commonly used to investigate gas‐stirred processes in steelmaking practice. The argon oxygen decarburization (AOD) converter is among various processes widely used in the metallurgy field and utilizes side blowing of oxygen and inert gas for mixing in the bath. Herein, the effect of the converter inclination on mixing time and jet‐penetration length with a side‐blown physical model is investigated. Scaling with the modified Froude number is applied on data from a real industrial AOD converter to achieve a system with reasonable gas flow rates. During the experiments, water is used to simulate liquid steel and air is blown through side‐mounted nozzles for stirring. A NaCl tracer is added and subsequent conductivity measurements are used to measure mixing time. Overall, the penetration length is shown to be independent of inclination angle. The mixing time is found to be influenced by the change of bath height to diameter ratio, change of geometry in the bath volume, gas flow rate, and the intensified wave motion at the interface caused by the inclination of the vessel. The mixing time increase with 14% when 14° angle is applied.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.