Abstract
Abstract Objective: To compare the incidence of nonelective removal of single-lumen silicone and dual-lumen polyurethane percutaneously inserted central catheters (PICCs). Study Design: A prospective cohort study was conducted with neonates in whom 247 PICC lines had been successfully inserted. Patients were assigned to either the single-lumen silicone group or the dual-lumen polyurethane group and nonelective removal incidence was compared using a logistic regression model. Results: Incidence of nonelective removal in dual-lumen polyurethane PICCs (n =91) was 48.3% versus 34% in single-lumen silicone PICCs (n =156). Thus, dual-lumen polyurethane catheters had a significantly increased chance of nonelective removal compared with single-lumen silicone PICCs (P =.004). The most usual complication in dual-lumen polyurethane PICCs was suspected catheter-related bloodstream infection; in single-lumen silicone PICCs it was external rupture. Conclusions: Dual-lumen polyurethane PICCs are associated with higher rates of nonelective removal and complications such as suspected catheter-related bloodstream infection. Cautious nursing care is necessary to prevent complications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.