Abstract

To evaluate the frequency, type, and predictors of intraoperative adverse events during donor hepatectomy for living-donor liver transplant. Retrospective analyses of the data from 182 consecutive living-donor liver transplant donors between May 2002 and September 2008. Ninety-one patients (50%) had at least 1 intraoperative adverse event including hypothermia (39%), hypotension (26%), need for transfusions (17%), and hypertension (7%). Patients with an adverse event were older (P = .001), had a larger graft weight (P = .023), more frequently underwent a right hepatectomy (P = .019), and were more frequently classified as American Society of Anesthesiologists physical status class II (P = .027) than those who did not have these adverse events. Logistic regression analysis revealed that only age (95% confidence interval 1.018-1.099; P = .001) was a risk factor for intraoperative adverse events. Patients with these adverse events more frequently required admission to the intensive care unit and were hospitalized longer postoperatively. A before and after analysis showed that after introduction of in-line fluid warmers and more frequent use of acute normovolemic hemodilution, the frequency of intraoperative adverse events was significantly lower (80% vs 29%; P < .001). Intraoperative adverse events such as hypothermia and hypotension were common in living-donor liver transplant donors, and older age was associated with an increased risk of these adverse events. However, the effect of these adverse events on postoperative recovery is not clear.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call