Abstract

The National Institute for Occupational Safety and Health (NIOSH) has investigated engineering noise controls to reduce sound levels in cabs on air-rotary drill rigs. A recent investigation revealed that some drillers are exposed to A-weighted sound levels exceeding 85 dB even though a cab is used. NIOSH studied the in-cab sound levels of one such rig. First, preliminary tests were conducted in a controlled environment using accelerometers and microphones with spectral analysis to identify the dominant noise sources for in-cab sound levels. The results indicate that vibration transmitted from multiple hydraulic pumps to the control panel produces a dominant spike in the sound level spectrum in the 400 Hz 1/3-octave band. Next, field tests were performed in a production environment to evaluate noise controls to reduce in-cab sound levels. It was found that utilizing hydraulic noise suppressors reduces the structure-borne noise transmitted to the control panel. Further, using hydraulic noise suppressors and enhancing soundproofing reduced the in-cab A-weighted sound levels by as much as 4 dB.