Abstract

High-pressure (HP) CO 2 treatment was applied to disinfect a fabric which is frequently used in hospitals. The physical properties of the treated textile were evaluated and found not to be negatively influenced. Subsequently, the significance of the main parameters influencing the disinfection process were determined using multi-factor analysis of variance. Efficacy of the developed technique was demonstrated and optimised for Gram-negative Escherichia coli and Gram-positive Micrococcus luteus. Water addition was found to be crucial for the reduction of both bacteria species. Complete inactivation was achieved at temperatures as low as 20 °C for E. coli and 65 °C for M. luteus, respectively. The effective pressure required for the disinfection was only 50 bar. Finally, based on the experimentally revealed results, an empirical non-linear model was developed describing the inactivation of E. coli and M. luteus in the low-temperature process using highly compressed liquid, gaseous or supercritical CO 2.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.