Abstract

ABSTRACT An electrochemical treatment system consisting of a pulsed electrical power supply and an electrical treatment chamber was designed and evaluated for inactivation Listeria monocytogenes in recirculated brine for chilling processed bacons. The brine was tested under different currents and temperatures. An average D‐value of 1.61 min in the storage tank could be achieved at 7 mA/cm3 current with the fresh brine (t = 0 h). For the spent brine (t = 20 h), the D‐value was 2.5 min in the treatment chamber at 35 mA/cm3. The average D‐values in the treatment chamber were approximately 2.5 min at all three temperatures (4, 0, ‐8 8C) at 35 mA/cm3.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.