Abstract

In this study the suitability of a thin-film reactor (TFR) equipped with special flow guiding elements (FGE) was examined to analyse its capability to inactivate microorganisms in milk. Experiments were carried out with UHT-milk inoculated with Escherichia coli (E. coli), DH5α and Listeria innocua (L. innocua) WS 2258. Furthermore, the inactivation of microorganisms originally occurring in raw milk was investigated. E. coli, DH5α and L. innocua serving as biodosimeter were reduced by 4.58-log and 3.19-log, respectively. In milk, the original microorganisms showed a 4-log reduction. Without FGE the reduction was below 0.13-log. Thus, it can be derived that the efficacy of a UV-C thin-film reactor processing absorptive media like milk can be highly improved using FGE.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.