Abstract

RationaleBioresorbable scaffolds may confer clinical benefit in long-term studies; early mechanistic studies using intravascular imaging have provided insightful information about the immediate and mid-term local serial effects of BRS on the coronary vessel wall. ObjectivesWe assessed baseline, 6- and 12-month imaging data of the drug-eluting absorbable metal scaffold (DREAMS 2G). Methods and resultsThe international, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to 2 de novo lesions (in vessels of 2.2 to 3.7mm). Angiographic based vasomotion, curvature and angulation were assessed; intravascular ultrasound (IVUS) derived radiofrequency (RF) data analysis and echogenicity were evaluated; optical coherence tomography (OCT) attenuation and backscattering analysis were also performed.There was hardly any difference in curvature between pre-procedure and 12months (−0.0019; p=0.48). The change in angulation from pre- to 12months was negligible (−3.58°; 95% CI [−5.97, −1.20]), but statistically significant. At 6months, the change in QCA based minimum lumen diameter in response to high dose of acetylcholine and IVUS-RF necrotic core percentage showed an inverse relationship (estimate of −0.489; p=0.055) and with fibrous volume a positive relationship (estimate of 0.53, p=0.035). Bioresorption analysis by OCT showed that the maximum attenuation values decreased significantly from post-procedure at 6months (Δ 6months vs. post-proc. is −13.5 [95% CI −14.6, −12.4]) and at 12months (Δ 12months vs. post-proc. is −14.0 [95% CI −15.4, −12.6]). By radiofrequency data, the percentage of dense calcium decreased significantly from post-procedure at 6months and at 12months. Likewise, by echogenicity, hyperechogenic structures decreased significantly from post-procedure at 6months; thereafter, they remained unchanged. ConclusionFollowing implantation of DREAMS 2G, restoration of the vessel geometry, vasomotion and bioresorption signs were observed at up to 12months; importantly, these changes occurred with preservation of the lumen size between 6 and 12months.NCT01960504

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.