Abstract

This work assesses ultrasound's reproducibility for monitoring enamel thickness in vivo. This clinical reproducibility study recruited 30 healthy consenting volunteers. The enamel thickness on an intact maxillary central incisor was evaluated at 3 sites on 3 separate visits, 1 week apart. Bland-Altman statistical test and intraclass coefficients (ICC) were used to assess reproducibility. Reproducibility results were highest for the cervical site (bias [mm] = -0.01; 95% limits of agreement = -0.05, 0.04), followed by midbuccal (bias = 0.01; 95% limits of agreement = -0.04, 0.06) and incisal site (bias = 0; 95% limits of agreement = -0.25, 0.25). ICC was highest for the cervical site (0.96) followed by midbuccal (0.71). Ultrasound is a sufficiently reproducible and reliable technique for monitoring change in enamel thickness, as in erosive tooth surface loss (TSL). The preferred sites for ultrasonographic measurements are cervical and midbuccal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.