Abstract

Background: Danshen, a traditional Chinese medicine used in the management of cardiovascular diseases, is available without prescription in the US. Because Danshen is used to treat cardiovascular diseases, we studied the potential interference of Danshen with serum digoxin measurement using various immunoassays. Methods: Blood was collected 1 day before and then 1 and 2 h after feeding mice with Danshen. The apparent digitoxin activities were measured by the fluorescence polarization immunoassay (FPIA). We also added microliter amounts of Danshen extract to digoxin pools prepared from patients receiving digoxin. The digoxin concentrations were measured using the fluorescence polarization immunoassay (FPIA), microparticle enzyme immunoassay (MEIA) and chemiluminescent assay (CLIA). The observed values were compared with original values. We also fed mice with Danshen. Results: We observed measurable digoxin-like immunoreactivity in sera of mice after feeding with Danshen. We also observed falsely lower digoxin concentrations (negative interference) when MEIA was used for digoxin measurement. However, serum digoxin concentrations were falsely elevated with FPIA. We observed no interference of Danshen in serum digoxin measurement using the CLIA. Conclusions: Danshen appears to contain digoxin-like immunoreactivity but does not interfere with serum digoxin measurement when CLIA was used.