Abstract

Methods for local photon path length and optical properties estimation, based on measured and simulated diffuse reflectance within 2 mm from the light source, are proposed and evaluated in vivo on Caucasian human skin. The accuracy of the methods was good (2%-7%) for path length and reduced scattering but poor for absorption estimation. Reduced scattering and absorption were systematically lower in the fingertip than in the forearm skin (633 nm). A maximum intrasite and interindividual variation of approximately 35% in an average photon path length was found. The methodology was applied in laser Doppler flowmetry, where path-length normalization of the estimated perfusion removed the optical property dependency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.