Abstract

In vivo tissue responses were compared for three commercially available polypropylene suburethral slings that differ markedly in fabric structure and in size of resulting interstices and pores. All three elicited the same basic inflammatory response; however, individual fabric structures produced distinct differences in tissue formation within each mesh. The presence of numerous, closely spaced, small diameter filaments prevented formation of extensive fibrous connective tissue within two slings (ObTape and IVS Tunneller mesh). The much larger diameter monofilament and open knit structure of the Monarc sling permitted the most extensive fibrous tissue integration. These differences may be of interest to physicians considering clinical use.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.