Abstract

BackgroundLittle is known about normal in vivo mechanics of the glenohumeral joint. Such an understanding would have significant implications for treating disease conditions that disrupt shoulder function. The objective of this study was to determine articular contact locations between the glenoid and humeral articular surfaces in normal subjects during shoulder abduction with neutral, internal, and external rotations. We hypothesized that glenohumeral articular contact is not perfectly centered and is variable in normal subjects tested under physiological loading conditions. MethodsOrthogonal fluoroscopic images and magnetic resonance image-based computer models were used to characterize the centroids of articular cartilage contact of the glenohumeral joint at various static, actively stabilized abduction and rotation positions in five healthy shoulders. The shoulder was investigated at 0°, 45°, and 90° abduction with neutral rotation and then at 90° abduction combined with active maximal external rotation and active maximal internal rotation. ResultsFor all the investigated positions, the centroid of contact on the glenoid surface for each individual, on average, was more than 5 mm away from the geometric center of the glenoid articular surface. Intersubject variation of the centroid of articular contact on the glenoid surface was observed with each investigated position, and 90° abduction with maximal internal rotation showed the least variability. On the humeral head surface, the centroids of contact were located at the superomedial quarter for all investigated positions, except in two subjects’ positions at 0° abduction, neutral rotation. ConclusionsThe data showed that the in vivo glenohumeral contact locations were variable among subjects, but in all individuals they were not at the center of the glenoid and humeral head surfaces. This confirms that “ball-in-socket” kinematics do not govern normal shoulder function. These insights into glenohumeral articular contact may be relevant to an appreciation of the consequences of pathology such as rotator cuff disease and instability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.