Abstract

To map the 3-dimensional (3D) strain of the optic nerve head (ONH) invivo after intraocular pressure (IOP) lowering by trabeculectomy (TE) and to establish associations between ONH strain and retinal sensitivity. Observational case series. Nine patients with primary open-angle glaucoma (POAG) and 3 normal controls. The ONHs of 9 subjects with POAG (pre-TE IOP: 25.3±13.9 mmHg; post-TE IOP: 11.8±8.6 mmHg) were imaged (1 eye per subject) using optical coherence tomography (OCT) (Heidelberg Spectralis, Heidelberg Engineering GmbH, Heidelberg, Germany) before (<21 days) and after (<50 days) TE. The imaging protocol was repeated for 3 controls in whom IOP was not altered. In each post-TE OCT volume, 4 tissues were manually segmented (prelamina, choroid, sclera, and lamina cribrosa [LC]). For each ONH, a 3D tracking algorithm was applied to both post- and pre-TE OCT volumes to extract IOP-induced 3D displacements at segmented nodes. Displacements were filtered, smoothed, and processed to extract 3D strain relief (the amount of tissue deformation relieved after TE). Strain relief was compared with measures of retinal sensitivity from visual field testing. Three-dimensional ONH displacements and strain relief. On average, strain relief (averaged or effective component) in the glaucoma ONHs (8.6%) due to TE was higher than that measured in the normal controls (1.07%). We found no associations between the magnitude of IOP decrease and the LC strain relief (P > 0.05), suggesting biomechanical variability across subjects. The LC displaced posteriorly, anteriorly, or not at all. Furthermore, we found linear associations between retinal sensitivity and LC effective strain relief (P < 0.001; high strain relief associated with low retinal sensitivity). We demonstrate that ONH displacements and strains can be measured invivo and thatTEcanrelieve ONH strains. Our data suggest a wide variability in ONH biomechanics in the subjects examined inthis study. We further demonstrate associations between LC effective strain relief and retinal sensitivity.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.