Abstract

The in vitro EpiSkin™ test method was validated in 2007 by the European Union Reference Laboratory for alternatives to animal testing (EURL ECVAM) as a full replacement method for the Draize acute skin irritation test and adopted in the OECD Test Guideline 439 in 2009. Based on the EpiSkin™ technology, the production of a reconstructed epidermis model has been established and standardized in China. The evaluation of the in vitro skin irritation test method using this EpiSkin™ model produced in China was performed on a set of 45 chemicals. Good predictive capacity was obtained with 94% (n=17) for sensitivity, 75% (n=28) for specificity and 82% for accuracy. The accuracy of the included 20 OECD reference chemicals also met the OECD acceptance criteria, indicating that this testing method based on the EpiSkin™ model produced in China can be used as a stand-alone test method to predict skin irritation. The availability and validity of in vitro epidermis model and testing method are of great significance for extending the applications of non-animal alternative testing methods in China.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.