Abstract

Biodegradable polymeric devices were evaluated in vitro for intravitreal drug delivery. The matrix (short-term drug delivery) and the porous (longer-term drug delivery) reservoir devices were made from polycaprolactone of two molecular weights (30,000 and 56,000). Matrix devices were loaded with 5-fluorouracil or ganciclovir. Porous reservoirs were loaded with 5-fluorouracil, ganciclovir, 5-carboxyfluorescein, or foscarnet. The release was monitored in phosphate-buffered solution using ultraviolet spectrophotometry. Release from the matrix devices was characterized by an initial burst, followed by a nonlinear release. The porous reservoirs demonstrated zero order linear release of drugs, sustained up to 250 days in this experiment. The matrix device is capable of sustained release over several months; the porous reservoir can deliver drugs for over 1 year. Further studies are needed to evaluate in vivo biodegradation behavior and toxicity of drugs used for sustained release.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.