Abstract
22 specimens prepared with Cention and RMGIC were embedded in primary teeth mounted in acrylic for analysing shear bond strength. Shear bond strength was analysed using a universal testing machine. The modes of failure in samples were observed under a stereomicroscope and scanning electron microscope. 22 customised samples of Cention N and RMGIC were prepared and categorised as group A and group B, respectively. The flexural and compressive strengths of these samples were evaluated using a universal testing machine. The shear bond strength of RMGIC was higher than that of Cention N, whereas the compressive and flexural strengths of Cention N were significantly higher than those of RMGIC. The modes of failure were predominantly adhesive followed by mixed failures. The results of this study suggest that Cention N demonstrated superior mechanical properties compared with RMGIC and can therefore be recommended for restorations in primary posterior teeth. Cention N being a smart, esthetic, self-cured, or dual-cured material with better mechanical properties offers a wide range of applicability in primary teeth.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.