Abstract

This study evaluated the color aging of two computer aided design/computer aided manufacturing (CAD/CAM) provisional materials of different compositions (polymethyl methacrylate and composite resin) after exposure to thermal aging and immersion in coffee for 3, 6, and 12 intraoral months. The current in vitro study was conducted from September to December 2021 at the Craniofacial laboratory at the Saint Joseph University in Beirut, Lebanon. The shades of 2.0 mm thick, 10.0 mm in diameter disk shaped specimens of VITA CAD Temp® and Ceramill® TEMP were measured using the VITA Linearguide 3D MASTER® and a conversion table to extract the CIE LFNx01aFNx01bFNx01 values on a white background (n = 30). The color differences ΔE at 3, 6, and 12 months were calculated and analyzed by repeated measures ANOVA followed by Bonferroni multiple comparisons, univariate analyses, and one sample t tests. The mean ΔET1/T0, ΔET2/T0, and ΔET3/T0 values were significantly higher than the cutoff values for acceptability and perceptibility for the VITA CAD Temp® and the Ceramill® TEMP groups. In addition, the increase in ΔE overtime was significantly greater in the Ceramill® TEMP group compared to the VITA CAD Temp® group. The Ceramill® TEMP changed color more and faster than the VITA CAD Temp®. In addition, whether at 3, 6, or 12 months, the color variations of both materials are not only perceptible but also unacceptable compared to the initial shade.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call