Abstract

The effects of lasing parameters on the precipitation of hydroxyapatite (HA) on the commercial Ti6Al4V alloy in simulated body fluid (SBF) were investigated. Ti6Al4V plates were polished and ultrasonically cleaned in acetone and ethyl alcohol, respectively. The specimen surfaces were treated with Er:YAG laser using super short pulse (SSP, 50μs) and very short pulse (VSP, 100μs) modes. Surface roughness was measured before and after laser treatment. The specimens were immersed in simulated body fluid (SBF) for 1, 3, and 7days and, then the amount of Ca and P precipitation on specimens was determined using SEM/EDS analysis. An average roughness varying between 0.19 and 0.81μm in surface roughness was detected in all laser-treated specimens depending on the lasing parameters. The highest surface roughness and Ca precipitation were found in VSP group (20Hz and 5W). Laser treatment of specimen surfaces has dramatically increased the HA precipitation due to the increasing surface roughness. It is also concluded that the immersion time was effective on the HA precipitation as well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.