Abstract

Summary In vitro and in vivo fluid flow rates of 14-, 16-, 18-, and 20-gauge catheters at fluid heights of 0.91 and 1.75 m above the catheters were determined. Flow rates were significantly faster in vitro than in vivo, at a greater height, and with larger catheter radius. In vivo flow rates averaged 7% less than in vitro flow rates. Fluid flow increased approximately 50% for each gauge catheter when the height was raised from 0.91 to 1.75 m. Flow rates increased linearly with increasing catheter radius. The flow rate of each gauge of catheter was significantly different from flow rates of all other gauges that were used. In vivo flow rates for 14-, 16-, 18-, and 20-gauge catheters at fluid heights of 0.91 and 1.75 m were 137, 88, 75, and 45 ml/min and 206, 152, 114, and 75 ml/min, respectively. Knowledge of flow rates allows selection of a catheter gauge that will provide adequate volume loading for the size of patient being treated in the time needed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.